A Dutch manufacturer of supersonic separators, was running a test field with gas from the public gas supply net, just allowing to add small amounts of liquids. For better test conditions the customer was looking for a technical solution to run the test in a closed loop. Bornemann proposed to install a multiphase pump MPC 335-100 and thereby to increase the pressure after the separator from 20 barg to 36 barg. After the pump installation in September 2005 the test field has been in successful operation for several tests.
| Medium: | oil, gas, water |
| Gas rate: | 23.6 MMSCFD |
| Liquid rate: | 760 BLPD |
| Oil viscosity: | 1 cSt |
| Inlet pressure: | 312 psig |
| Outlet pressure: | 530 psig |
| Speed range: | 600 - 1,750 rpm |
| Absorbed power: | 825 hp |
| Pump and system pressure rating: | ANSI 600 lbs |
| << back |